Innovative Heat Transfer · Calgary, Alberta

Innovative Heat Transfer · Calgary, Alberta

TO THE PLANT OR REFINERY WHO WANTS TO SAVE TIME ON EACH SAMPLE
Cool samples to a safe testing temperature fast with expert-designed sample cooling coils.
A hot sample pulled straight from a high-pressure line flashes to steam. That puts your team and equipment at risk and skews test results. Shutting down the line to cool isn’t an option, either. Our cooling coils bring samples down to testing temperature in a sealed coil while your systems continue to run.

How to Get Your Cooling Coils
01 · Fill out the form below
02 · Request data sheet
03 · Speak to an engineer
Sample while you run – no shutdown. No waiting.
Ensure your results reflect what’s actually in your process.
Safeguard your testing equipment against damage.
Each Hot Sample Is A Waiting Game Or A Guessing Game
Steam from a boiler or a hot sample from any process – a sample isn’t useful until it’s cold enough to test, and all workarounds cost you something. Wait it out, and your team loses time. Shut it down, and you lose production. Test it hot, and you risk burns, damaged equipment, and inconsistent test results.
Harness The Power Of Sample Cooling Coils – Across All Major Industries
These coolers were first built for our own high-pressure steam generators, where a bad sample isn’t an option. Forty years and hundreds of sold units later, we custom-engineer them for any and all operations that need their hot samples cooled – safely.

01 / FOR POWER GENERATION
Condensate and steam samples come off the line hot enough to flash and throw the readings your operation relies on into jeopardy. Our coolers guide samples down in a sealed coil, allowing you to test while your unit stays online.

02 / REFINERIES AND PETRO-CHEMICAL
Pulling a sample from a hot, high-pressure line puts operators in the crosshairs of flash steam. Our coolers keep the stream sealed until it’s cool enough to handle and test safely.

03 / CHEMICAL PROCESSING
High-temperature steams are hard on the wrong materials, and a failing coil puts both your people and your results at risk. We build each cooler based on your custom material and wall thickness requirements.

04 / OIL & Gas
Our sample coolers were originally designed for steam grab samples on TIW’s OTSG packages, where conditions are hard and downtime is costly. Forty years later, we custom-engineer them for all oil and gas processes that require a cooled sample.

05 / WASTEWATER & WATER
Treatment water often carries solids that clog tight bends, and a plugged cooler means missed tests. Our coils have no sharp bends and drain fully, so they stay clear and easy to clean.

06 / PHARMACEUTICALS
When a product’s quality depends on your steam and water systems, a contaminated sample raises compliance questions. Our coolers work in a sealed coil that keeps contaminants out.

07 / INDUSTRIAL MANUFACTURING
Boilers and hot process lines require regular testing but shutting down to sample costs time. Our coolers let you pull a safe sample while the line continues running.

08 / BREWERIES
Samples have to cool before you can trust a gravity or pH reading, and ice baths and waiting around slow down the process. Our coolers bring samples to reading temperature in a sealed coil, right from your kettle or mash tun.
(No Obligations. No Commitment.)

Each unit supplied with a Canadian Registration Number (CRN) and is suitable for installation in ASME B31.3 piping systems.
What do our customers have to say?
Discover What Sample Cooler Coils Can Do For Your Business
The sample cooler on your steam generator has splintered. Steam grab samples have to wait for the next planned shutdown.
A replacement coil built for that steam generator’s pressure and temperature lets operators pull steam samples every shift with the unit online.
Water flashes as it leaves the sample line and drives off neutralizing amine. pH reads low, so your team feeds more chemical than the system needs.
The sample cools in a sealed coil to within about 5°C of your cooling water. pH reads true, and you dose only what’s needed.
An operator cracks a valve on a high-pressure line into an open container. Part of the sample flashes to steam around their hands.
The sample remains sealed in the coil, coming out cool enough to hold. The high-pressure tube has no external connections to leak.
01 / Contact Us
02 / Let's Connect
03 / Let'S Get Technical
Frequently Asked Questions
On top of increasing your time spend, it’s a question of safety. A sudden drop in pressure can cause process fluid to flash into steam. This is not only a hazard to workers and equipment, but poses a threat to the sample itself.
No – to keep downtime to an absolute minimum, you can keep your system running and monitor it throughout the process.
We supply a variety of versatile materials to suit all applications: Carbon steel, stainless steel, duplex stainless steel, Inconel, and Monel on the sample side combined with carbon or stainless steel on the cooling side. If your process demands a specific material not listed, let us know using the form below or give us a call at 403-279-8310.
Yes, the system is modular and built from standard tube fittings with tube extensions available at custom connection points.
Our sample coolers make maintenance easy. The coil has no sharp bends, and both the inner and outer coils drain completely.
Yes. We pride ourselves on being a safe, reliable operation – each of our units ship with a Canadian Registration Number (CRN) and is suitable for ASME B31.3 piping systems.
We keep a variety of materials in stock to minimize lead time on the most popular models and can ship within Canada or internationally.
Getting the consistent results you need starts with this simple form.
© Copyright TIW Western Inc.